|
|
||||||||
Original Articles |
Nasal intermittent positive pressure ventilation (NIPPV) has been widely used in the treatment of chronic respiratory disease. Ventilators may be volume or pressure preset; each type has theoretical advantages, but to date there has been no formal comparison. We wanted to assess the efficacy on blood gas changes that may be achieved and overall acceptability of four nasal ventilators (two pressure preset: Respironics bilevel positive airway pressure (BiPAP) and the Thomas NIPPY; and two volume preset: BromptonPac and Monnal-D) in patients with stable chronic respiratory failure. Median age was 59 yrs (range 48-71 yrs), mean (SD) arterial oxygen tension (PaO2) 7.16 (0.21) kPa, arterial carbon dioxide tension (PaCO2) 7.02 (0.35) kPa, forced expiratory volume in one second (FEV1) 0.76 (0.24) l, and forced vital capacity (FVC) 1.58 (0.49) l. All had previously used NIPPV. There were significant changes in blood gases at 2 h with each ventilator: mean change (95% confidence interval); BiPAP PaO2 +1.52 (0.95-2.09) kPa, PaCO2-1.04 (1.55-0.54) kPa; NIPPY PaO2 +1.63 (0.85-2.41) kPa, PaCO2, -1.1 (1.86-0.34) kPa; BromptonPac PaO2 +1.22 (0.75-1.67) kPa, PaCO2 -1.14 (1.52-0.76) kPa; Monnal-D PaO2 +1.14 (0.42-1.84) kPa, PaCO2 -1.19 (2.14-0.23) kPa. Analysis of variance showed no significant differences in the efficacy of volume or pressure preset equipment, and all ventilators proved equally acceptable to the patients studied. We conclude that all four of the volume or pressure preset ventilators examined are suitable for the delivery of nasal intermittent positive pressure ventilation in patients with stable chronic respiratory failure.
This article has been cited by other articles:
![]() |
J M Tuggey and M W Elliott Randomised crossover study of pressure and volume non-invasive ventilation in chest wall deformity Thorax, October 1, 2005; 60(10): 859 - 864. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. J. Lloyd-Owen, G. C. Donaldson, N. Ambrosino, J. Escarabill, R. Farre, B. Fauroux, D. Robert, B. Schoenhofer, A. K. Simonds, and J. A. Wedzicha Patterns of home mechanical ventilation use in Europe: results from the Eurovent survey Eur. Respir. J., June 1, 2005; 25(6): 1025 - 1031. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Winck, M. Vitacca, A. Morais, L. Barbano, R. Porta, A. Teixeira-Pinto, and N. Ambrosino Tolerance and Physiologic Effects of Nocturnal Mask Pressure Support vs Proportional Assist Ventilation in Chronic Ventilatory Failure Chest, August 1, 2004; 126(2): 382 - 388. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-P. Janssens, S. Derivaz, E. Breitenstein, B. de Muralt, J.-W. Fitting, J.-C. Chevrolet, and T. Rochat Changing Patterns in Long-term Noninvasive Ventilation: A 7-Year Prospective Study in the Geneva Lake Area Chest, January 1, 2003; 123(1): 67 - 79. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Vitacca, L. Barbano, S. D'Anna, R. Porta, L. Bianchi, and N. Ambrosino Comparison of Five Bilevel Pressure Ventilators in Patients With Chronic Ventilatory Failure: A Physiologic Study Chest, December 1, 2002; 122(6): 2105 - 2114. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.P. Highcock, E. Morrish, S. Jamieson, J.M. Shneerson, and I.E. Smith An overnight comparison of two ventilators used in the treatment of chronic respiratory failure Eur. Respir. J., October 1, 2002; 20(4): 942 - 945. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Clini, C. Sturani, A. Rossi, S. Viaggi, A. Corrado, C.F. Donner, and N. Ambrosino The Italian multicentre study on noninvasive ventilation in chronic obstructive pulmonary disease patients Eur. Respir. J., September 1, 2002; 20(3): 529 - 538. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.A. Wedzicha and J-F. Muir Noninvasive ventilation in chronic obstructive pulmonary disease, bronchiectasis and cystic fibrosis Eur. Respir. J., September 1, 2002; 20(3): 777 - 784. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Cuvelier and J-F. Muir Noninvasive ventilation and obstructive lung diseases Eur. Respir. J., June 1, 2001; 17(6): 1271 - 1281. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.P. Highcock, J.M. Shneerson, and I.E. Smith Functional differences in bi-level pressure preset ventilators Eur. Respir. J., February 1, 2001; 17(2): 268 - 273. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Vitacca, S. Nava, M. Confalonieri, L. Bianchi, R. Porta, E. Clini, and N. Ambrosino The Appropriate Setting of Noninvasive Pressure Support Ventilation in Stable COPD Patients Chest, November 1, 2000; 118(5): 1286 - 1293. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. GARROD, C. MIKELSONS, E. A. PAUL, and J. A. WEDZICHA Randomized Controlled Trial of Domiciliary Noninvasive Positive Pressure Ventilation and Physical Training in Severe Chronic Obstructive Pulmonary Disease Am. J. Respir. Crit. Care Med., October 1, 2000; 162(4): 1335 - 1341. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Guilleminault, P. Philip, and A. Robinson Sleep and neuromuscular disease: bilevel positive airway pressure by nasal mask as a treatment for sleep disordered breathing in patients with neuromuscular disease J. Neurol. Neurosurg. Psychiatry, August 1, 1998; 65(2): 225 - 232. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |