ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chowienczyk, P.
Right arrow Articles by Cochrane, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chowienczyk, P.
Right arrow Articles by Cochrane, G.
Eur Respir J 1991; 4: 623-628
Copyright © ERS Journals Ltd 1991


Original Articles

A flow interruption device for measurement of airway resistance

PJ Chowienczyk, CP Lawson, S Lane, R Johnson, N Wilson, M Silverman, and GM Cochrane

Unlike conventional methods, the interrupter method for measuring airway resistance is non-invasive and requires minimal patient co-operation. It can therefore be applied in critically ill patients, acute asthmatics, neonates, pre-school children, geriatric patients and unconscious patients. The method is based on transient interruption of airflow at the mouth for a brief period during which alveolar pressure equilibrates with mouth pressure. Measurement of mouth pressure is used to estimate alveolar pressure prior to interruption and the ratio of this to flow prior to interruption gives airway resistance. Using the interrupter method we have developed a portable device for measuring airway resistance which is simple to use and gives a direct instantaneous reading. Measurements of airway resistance obtained using the new device were compared with those obtained using conventional body plethysmograph methods in 43 adult patients. A close correlation was seen (r = 0.86). The two methods appear equally sensitive in detecting changes in airway resistance following bronchodilator therapy. The device has been used successfully in pre-school children unable to co-operate with conventional methods.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
N. Beydon, S. D. Davis, E. Lombardi, J. L. Allen, H. G. M. Arets, P. Aurora, H. Bisgaard, G. M. Davis, F. M. Ducharme, H. Eigen, et al.
An Official American Thoracic Society/European Respiratory Society Statement: Pulmonary Function Testing in Preschool Children
Am. J. Respir. Crit. Care Med., June 15, 2007; 175(12): 1304 - 1345.
[Full Text] [PDF]


Home page
Eur Respir JHome page
Y. F. Guo, F. Herrmann, J-P. Michel, and J-P. Janssens
Normal values for respiratory resistance using forced oscillation in subjects >65 years old
Eur. Respir. J., October 1, 2005; 26(4): 602 - 608.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
P.J.F.M. Merkus, H.G.M. Arets, T. Joosten, A. Siero, M. Brouha, J.Y. Mijnsbergen, J.C. de Jongste, and C.K. van der Ent
Measurements of interrupter resistance: reference values for children 3-13 yrs of age
Eur. Respir. J., October 1, 2002; 20(4): 907 - 911.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child.Home page
S A McKenzie, E Chan, I Dundas, P D Bridge, C S Pao, M Mylonopoulou, and M J R Healy
Airway resistance measured by the interrupter technique: normative data for 2-10 year olds of three ethnicities
Arch. Dis. Child., September 1, 2002; 87(3): 248 - 251.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
N. Beydon, F. Amsallem, M. Bellet, M. Boule, M. Chaussain, A. Denjean, R. Matran, B. Wuyam, C. Alberti, and C. Gaultier
Pre/Postbronchodilator Interrupter Resistance Values in Healthy Young Children
Am. J. Respir. Crit. Care Med., May 15, 2002; 165(10): 1388 - 1394.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G.L. Hall, J.H. Wildhaber, M. Cernelc, and U. Frey
Evaluation of the interrupter technique in healthy, unsedated infants
Eur. Respir. J., December 1, 2001; 18(6): 982 - 988.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
E Lombardi, P D Sly, G Concutelli, E Novembre, G Veneruso, G Frongia, R Bernardini, and A Vierucci
Reference values of interrupter respiratory resistance in healthy preschool white children
Thorax, September 1, 2001; 56(9): 691 - 695.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
F. Child, S. Clayton, S. Davies, A.A. Fryer, P.W. Jones, and W. Lenney
How should airways resistance be measured in young children: mask or mouthpiece?
Eur. Respir. J., June 1, 2001; 17(6): 1244 - 1249.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
P. J. F. M. MERKUS, J. Y. MIJNSBERGEN, W. C. J. HOP, and J. C. de JONGSTE
Interrupter Resistance in Preschool Children . Measurement Characteristics and Reference Values
Am. J. Respir. Crit. Care Med., May 1, 2001; 163(6): 1350 - 1355.
[Abstract] [Full Text]


Home page
ChestHome page
K. R. Bock, P. Silver, M. Rom, and M. Sagy
Reduction in Tracheal Lumen Due to Endotracheal Intubation and Its Calculated Clinical Significance
Chest, August 1, 2000; 118(2): 468 - 472.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
V. Kessler, G. Mols, H. Bernhard, C. Haberthur, and J. Guttmann
Interrupter airway and tissue resistance: errors caused by valve properties and respiratory system compliance
J Appl Physiol, October 1, 1999; 87(4): 1546 - 1554.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the European Respiratory Society.