ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Knox, A.
Right arrow Articles by Tattersfield, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Knox, A.
Right arrow Articles by Tattersfield, A.
Eur Respir J 1991; 4: 497-502
Copyright © ERS Journals Ltd 1991


Original Articles

A comparison of the Yan and a dosimeter method for methacholine challenge in experienced and inexperienced subjects

AJ Knox, A Wisniewski, S Cooper, and AE Tattersfield

Bronchial reactivity is being measured with increasing frequency in epidemiological studies, but there debate continues about the relative merits of the different methods used to measure reactivity, particularly for subjects with no previous experience of reactivity testing as is the case in epidemiological studies. Repeatability is likely to improve with practice, and laboratory based studies on experienced subjects may overestimate the repeatability of a test in inexperienced subjects. We have compared the repeatability of the Yan method with a dosimeter (Mefar) method of administering methacholine to 40 asthmatic subjects: 20 with experience of methacholine challenge on at least six previous occasions and 20 with no previous experience. Subjects attended the laboratory on four days within a two week period, at the same time of day. A methacholine challenge was performed on two occasions using the Yan method and on two occasions using the dosimeter. Methacholine responsiveness was measured as the provocative dose causing a 20% reduction in forced expiratory volume in one second (PD20FEV1). Geometric mean PD20FEV1 values with the Yan method were 1.14 doubling doses (DD) of methacholine higher than with the dosimeter method. In the experienced subjects, the 95% range for a single estimate was +/- 1.56 DD for the Yan method and +/- 1.37 DD for the dosimeter method. In the inexperienced subjects, the 95% ranges were +/- 2.65 and +/- 1.87 DD for the Yan and dosimeter methods, respectively. Thus, the differences in repeatability between the Yan and dosimeter methods, were small; experienced subjects gave more repeatable values than inexperienced subjects.


This article has been cited by other articles:


Home page
ThoraxHome page
S Chinn and J P Schouten
Reproducibility of non-specific bronchial challenge in adults: implications for design, analysis and interpretation of clinical and epidemiological studies
Thorax, May 1, 2005; 60(5): 395 - 400.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
T. Gislason, C. Janson, P. Vermeire, P. Plaschke, E. Bjornsson, D. Gislason, and G. Boman
Respiratory Symptoms and Nocturnal Gastroesophageal Reflux : A Population-Based Study of Young Adults in Three European Countries
Chest, January 1, 2002; 121(1): 158 - 163.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
G De Meer, D J J Heederik, B Brunekreef, and D S Postma
Repeatability of bronchial hyperresponsiveness to adenosine-5'-monophosphate (AMP) by a short dosimeter protocol
Thorax, May 1, 2001; 56(5): 362 - 365.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. Crapo
Guidelines for Methacholine and Exercise Challenge Testing---1999 . THIS OFFICIAL STATEMENT OF THE AMERICAN THORACIC SOCIETY WAS ADOPTED BY THE ATS BOARD OF DIRECTORS, JULY 1999
Am. J. Respir. Crit. Care Med., January 1, 2000; 161(1): 309 - 329.
[Full Text]


Home page
BMJHome page
S. C O Taggart, A. Custovic, D. H Richards, and A. Woodcock
GR106642X: a new, non-ozone depleting propellant for inhalers
BMJ, June 24, 1995; 310(6995): 1639a - 1640.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the European Respiratory Society.