1 Dept of Paediatrics, Division Paediatric Respiratory Medicine, and 2 Dept of Epidemiology and Biostatistics, Erasmus University and University Hospital/Sophia Children's Hospital, Rotterdam and 3 Dept of Paediatrics, University Hospital Maastricht, the Netherlands
CORRESPONDENCE: J.C. de Jongste, Sophia Children's Hospital, Room Sp-2465, P.O. Box 2060, 3000 CB, Rotterdam, the Netherlands
Keywords: asthma, breath-hold, children, exhaled air, nitric oxide, off-line sampling
Received: April 26, 1999
Accepted January 24, 2001
This study was supported by a research grant of the Netherlands Asthma Foundation (NAF 94.14).
Measurement of nitric oxide in exhaled air is a noninvasive method to assess airway inflammation in asthma. This study was undertaken to establish the reference range of exhaled NO in healthy school-aged children and to determine the influence of ambient NO, noseclip and breath-holding on exhaled NO, using an off-line balloon sampling method.
All children attending a primary school (age range 813 yrs) underwent NO measurements on two occasions with high and low ambient NO. Each time, the children performed four expiratory manoeuvres into NO-impermeable balloons, with and without 10 s of breath-holding and with and without wearing a noseclip. Exhalation flow and pressure were not controlled. NO was measured within 4 h after collection, by means of chemiluminescence. All children completed a questionnaire on respiratory and allergic disorders, and performed flow/volume spirometry.
With low ambient NO, the mean exhaled NO value of 72 healthy children with negative questionnaires and normal lung function was 5.1±0.2 parts per billion (ppb) versus a mean of 6.8±0.3 ppb in the remaining 49 children with positive questionnaires for asthma and allergy, and/or recent symptoms of cold (p=0.001). Exhaled and ambient NO were significantly related, especially with ambient NO >10 ppb (r=0.86, p=0.0001 versus r=0.34, p=0.004 for ambient values <10 ppb). The use of a noseclip, with low ambient NO and without breath-holding, caused a small decrease in exhaled NO values (p=0.001). The effect of breath-holding on exhaled NO depended on ambient NO. With ambient NO >10 ppb, exhaled NO decreased, whereas with ambient NO <10 ppb, exhaled NO increased after 10 s breath-hold.
It is concluded that off-line sampling in balloons is a simple and, hence, attractive method for exhaled nitric oxide measurements in children which differentiates between groups with and without self-reported asthma, allergy and colds, when ambient nitric oxide is <10 parts per billion. Wearing a noseclip and breath-holding affected measured values and should, therefore be standardized or, preferably, avoided.
This article has been cited by other articles:
![]() |
D R Taylor, M W Pijnenburg, A D Smith, and J C D Jongste Exhaled nitric oxide measurements: clinical application and interpretation Thorax, September 1, 2006; 61(9): 817 - 827. [Abstract] [Full Text] [PDF] |
||||
![]() |
ATS/ERS Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide, 2005 Am. J. Respir. Crit. Care Med., April 15, 2005; 171(8): 912 - 930. [Full Text] [PDF] |
||||
![]() |
P L P Brand and R J Roorda Usefulness of monitoring lung function in asthma Arch. Dis. Child., November 1, 2003; 88(11): 1021 - 1025. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.W.H. Pijnenburg, E.T. Lissenberg, W. Hofhuis, L. Ghiro, W.C.J. Hop, W.P. Holland, and J.C. de Jongste Exhaled nitric oxide measurements with dynamic flow restriction in children aged 4-8 yrs Eur. Respir. J., October 1, 2002; 20(4): 919 - 924. [Abstract] [Full Text] [PDF] |
||||
![]() |
Members of the Task Force:, E. Baraldi, J.C. de Jongste, B. Gaston, K. Alving, P.J. Barnes, H. Bisgaard, A. Bush, C. Gaultier, H. Grasemann, et al. Measurement of exhaled nitric oxide in children, 2001: E. Baraldi and J.C. de Jongste on behalf of the Task Force Eur. Respir. J., July 1, 2002; 20(1): 223 - 237. [Abstract] [Full Text] [PDF] |
||||