ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Highcock, M.P.
Right arrow Articles by Smith, I.E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Highcock, M.P.
Right arrow Articles by Smith, I.E.
Eur Respir J 2001; 17:268-273
Copyright ©ERS Journals Ltd 2001


Functional differences in bi-level pressure preset ventilators

M.P. Highcock, J.M. Shneerson and I.E. Smith

The Respiratory Support and Sleep Centre, Papworth Hospital, Papworth Everard, Cambridge, CB3 8RE, UK

CORRESPONDENCE: M.P. Highcock, The Respiratory Support and Sleep Centre, Papworth Hospital, Papworth Everard, Cambridge, CB3 8RE, UK. Fax: 44 1480 830620

Keywords: bi-level pressure ventilators, mechanical ventilators, noninvasive positive pressure ventilators, ventilator performance

Received: February 21, 2000
Accepted September 6, 2000

The performance of four bilevel positive pressure preset ventilators was compared.

The ventilators tested were; BiPAP ST30 (Respironics); Nippy2 (B+D Electrical); Quantum PSV (Healthdyne); and Sullivan VPAP II ST (Resmed). A patient simulator was used to determine the sensitivity of the triggering mechanisms and the responses to a leak within the patient circuit, and to changes in patient effort.

Significant differences (p<0.05) between the devices were seen in the trigger delay time and inspiratory trigger pressure. When a leak was introduced into the patient circuit, the fall in tidal volume (VT) was less than ten per cent for each ventilator. The addition of patient effort produced a number of changes in the ventilation delivered. Patient efforts of 0.25 s induced a variable fall in VT. An increase in VT was seen with some ventilators with patient efforts of 1 s but the effect was variable. Trigger failures and subsequent falls in minute volume were seen with the BiPAP and the Nippy2 at the highest respiratory frequency.

Differences in the responses of the ventilators are demonstrated that may influence the selection of a ventilator, particularly in the treatment of breathless patients with ventilatory failure.




This article has been cited by other articles:


Home page
Chronic Respiratory DiseaseHome page
J E Heffner
Management of the chronically ventilated patient with a tracheostomy
Chronic Respiratory Disease, July 1, 2005; 2(3): 151 - 161.
[Abstract] [PDF]


Home page
Eur Respir JHome page
M.P. Highcock, J.M. Shneerson, and I.E. Smith
Increased ventilation with NiIPPV does not necessarily improve exercise capacity in COPD
Eur. Respir. J., July 1, 2003; 22(1): 100 - 105.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
H. Prigent, C. Samuel, B. Louis, M.-F. Abinun, F. Zerah-Lancner, M. Lejaille, J.-C. Raphael, and F. Lofaso
Comparative Effects of Two Ventilatory Modes on Speech in Tracheostomized Patients with Neuromuscular Disease
Am. J. Respir. Crit. Care Med., January 15, 2003; 167(2): 114 - 119.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. Vitacca, L. Barbano, S. D'Anna, R. Porta, L. Bianchi, and N. Ambrosino
Comparison of Five Bilevel Pressure Ventilators in Patients With Chronic Ventilatory Failure: A Physiologic Study
Chest, December 1, 2002; 122(6): 2105 - 2114.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M.P. Highcock, E. Morrish, S. Jamieson, J.M. Shneerson, and I.E. Smith
An overnight comparison of two ventilators used in the treatment of chronic respiratory failure
Eur. Respir. J., October 1, 2002; 20(4): 942 - 945.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the European Respiratory Society.