ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Liistro, G
Right arrow Articles by Stanescu, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Liistro, G
Right arrow Articles by Stanescu, D
Eur Respir J 1999; 14: 185-190
Copyright © ERS Journals Ltd 1999


Original Articles

Expiratory flow limitation in awake sleep-disordered breathing subjects

G Liistro, C Veriter, M Dury, G Aubert, and D Stanescu

Increased upper airways (UA) collapsibility has been implicated in the pathogeny of sleep-disordered breathing (SDB). An increased UA instability during expiration has recently been shown in healthy subjects. The present study assessed UA collapsibility in SDB patients by applying negative pressure during expiration. Full-night polysomnography was performed in 16 subjects (all snorers) with a wide range of SDB, and in six healthy control subjects. Physical examination, spirometry, and maximal inspiratory and expiratory flow rates were within normal limits for all 22 subjects. Negative expiratory pressure (NEP) (-5 cmH2O) was applied during quiet breathing in seated and supine position. Flow limitation (FL) during NEP was expressed as the percentage of tidal volume during which expiratory flow was less than or equal to the flow recorded during quiet breathing (%FL). The mean desaturation index (DI) of the 16 subjects was 27.3+/-26.4 (+/-sD) and the average FL in supine position was 38.4+/-37.9%. A close correlation between %FL supine during wakefulness and DI during sleep (r=0.84, p<0.001) was found. All obstructive sleep apnoea subjects had >30%FL supine. There was no FL in the six control subjects. In conclusion, negative expiratory pressure application during expiration appears to be a useful, noninvasive method for the evaluation of subjects with sleep-disordered breathing. Present results suggest that upper airway collapsibility can be detected in these subjects during wakefulness.


This article has been cited by other articles:


Home page
ChestHome page
G. Insalaco, S. Romano, O. Marrone, A. Salvaggio, and G. Bonsignore
A New Method of Negative Expiratory Pressure Test Analysis Detecting Upper Airway Flow Limitation To Reveal Obstructive Sleep Apnea
Chest, October 1, 2005; 128(4): 2159 - 2165.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
P. M. A. Calverley and N. G. Koulouris
Flow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology
Eur. Respir. J., January 1, 2005; 25(1): 186 - 199.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
A Van Meerhaeghe, P Delpire, P Stenuit, and M Kerkhofs
Operating characteristics of the negative expiratory pressure technique in predicting obstructive sleep apnoea syndrome in snoring patients
Thorax, October 1, 2004; 59(10): 883 - 888.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
A. Baydur, L. Wilkinson, R. Mehdian, B. Bains, and J. Milic-Emili
Extrathoracic Expiratory Flow Limitation in Obesity and Obstructive and Restrictive Disorders: Effects of Increasing Negative Expiratory Pressure
Chest, January 1, 2004; 125(1): 98 - 105.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
E. Verin, T. Similowski, A. Teixeira, and F. Series
Discriminative power of phrenic twitch-induced dynamic response for diagnosis of sleep apnea during wakefulness
J Appl Physiol, January 1, 2003; 94(1): 31 - 37.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
S. Abdel Kafi, T. Serste, D. Leduc, R. Sergysels, and V. Ninane
Expiratory flow limitation during exercise in COPD: detection by manual compression of the abdominal wall
Eur. Respir. J., May 1, 2002; 19(5): 919 - 927.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
E Verin, C Tardif, F Portier, T Similowski, P Pasquis, and J F Muir
Evidence for expiratory flow limitation of extrathoracic origin in patients with obstructive sleep apnoea
Thorax, May 1, 2002; 57(5): 423 - 428.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
V. NINANE, D. LEDUC, S. A. KAFI, M. NASSER, M. HOUA, and R. SERGYSELS
Detection of Expiratory Flow Limitation by Manual Compression of the Abdominal Wall
Am. J. Respir. Crit. Care Med., May 1, 2001; 163(6): 1326 - 1330.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the European Respiratory Society.