|
|
||||||||
Original Articles |
The purpose of this study was to establish the phrenic nerve conduction time (PNCT) for magnetic stimulation and further assess the relatively new technique of anterior unilateral magnetic stimulation (UMS) of the phrenic nerves in evaluating the diaphragm electromyogram (EMG). An oesophageal electrode was used to record the diaphragm compound muscle action potential (CMAP) elicited by supramaximal percutaneous electrical phrenic nerve stimulation (ES) and UMS from eight normal subjects. The oesophageal electrode used for recording the CMAP was positioned at the level of the hiatus and 3 cm below. The diaphragm CMAP was also recorded from chest wall surface electrodes in five subjects. All of the phrenic nerves could be maximally stimulated with UMS. A clear plateau of the amplitude of the CMAP was achieved for the right and left phrenic nerves. The mean amplitudes of the CMAP recorded from the oesophageal electrode were, for the right side, 0.74+/-0.29 mV (mean+SD) for ES and 0.76+/-0.30 mV for UMS with maximal power output, and for the left side 0.88+/-0.33 mV for ES and 0.80+/-0.24 mV for UMS. PNCT measured by the oesophageal electrode with ES and UMS with maximal output were, for the right side, 7.0+/-0.8 ms and 6.9+/-0.8 ms, respectively, and for the left side 7.8+/-1.2 ms and 7.7+/-1.3 ms, respectively. However, the CMAP recorded from chest wall surface electrodes with UMS was unsuitable for the measurement of PNCT. The results suggest that unilateral magnetic stimulation of the phrenic nerves combined with an oesophageal electrode can be used to assess diaphragmatic electrical activity and measure the phrenic nerve conduction time.
This article has been cited by other articles:
![]() |
J. C. Glerant, N. Mustfa, W. D. Man, Y. M. Luo, G. Rafferty, M. I. Polkey, and J. Moxham Diaphragm electromyograms recorded from multiple surface electrodes following magnetic stimulation Eur. Respir. J., February 1, 2006; 27(2): 334 - 342. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Sharshar, N. S Hopkinson, S. Jonville, H. Prigent, R. Carlier, M. J Dayer, E. B Swallow, F. Lofaso, J. Moxham, and M. I Polkey Demonstration of a second rapidly conducting cortico-diaphragmatic pathway in humans J. Physiol., November 1, 2004; 560(3): 897 - 908. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Demoule, E. Verin, C. Locher, J.-P. Derenne, and T. Similowski Validation of surface recordings of the diaphragm response to transcranial magnetic stimulation in humans J Appl Physiol, February 1, 2003; 94(2): 453 - 461. [Abstract] [Full Text] [PDF] |
||||
![]() |
ATS/ERS Statement on Respiratory Muscle Testing Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624. [Full Text] [PDF] |
||||
![]() |
M. I. Polkey and J. Moxham Clinical Aspects of Respiratory Muscle Dysfunction in the Critically Ill Chest, March 1, 2001; 119(3): 926 - 939. [Full Text] [PDF] |
||||
![]() |
Y. M. LUO, R. A. LYALL, M. LOU HARRIS, G. F. RAFFERTY, M. I. POLKEY, and J. MOXHAM Quantification of the Esophageal Diaphragm Electromyogram with Magnetic Phrenic Nerve Stimulation Am. J. Respir. Crit. Care Med., November 1, 1999; 160(5): 1629 - 1634. [Abstract] [Full Text] |
||||
![]() |
Y M Luo, M I Polkey, R A Lyall, and J Moxham Effect of brachial plexus co-activation on phrenic nerve conduction time Thorax, September 1, 1999; 54(9): 765 - 770. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |